WebJan 8, 2024 · Most water heaters run on 240V, 3KW would require 12.5A. 120V (if such exists) would require 25A. 18.75 is neither. Most electric water heaters sold by Home Depot draw 4500W, this would require 18.75A which is a little marginal for a 12 gauge circuit. There are a few rated at 3800W at 15.83A. Share Improve this answer Follow WebMar 26, 2024 · A 120-volt water heater usually is equipped with a 1125 watt element. If your heater has a 2000 watt element, the amp draw can be easily calculated. 2000 / 120 = 16.667 amps. It appears at minimum, a 20 amp circuit will be required. The usual wire size for up to 20 amps is 12 AWG copper wire.
Installing a Electric Water Heater Circuit
WebJul 31, 2011 · The heater should state on it what the current draw is. The rule of thumb is that the circuit capacity (wiring) and protection (breaker) should exceed the max curent draw by 25%. Another way to look at it is that the max current draw should be 80% of the breaker and wiring capacity. WebApr 7, 2024 · SUITABLE FOR SMALL CARAVANS AND CAMPING: As portable as a tankless water heater, the IPX4 waterproof tested Kitchen Aid can be used for caravan showers, camping baths or sun showers in the yard. It is easy to install on caravan camping and picnic sinks. ... Recommended circuit breaker size: 15 amps, which ensures … reactive findindex
Is it ok to run a 30A water heater circuit on #12 wire?
WebWhat Size Breaker And Wire Do You Need For A 40-Gallon Water Heater? A 30A double pole breaker is often required for a 40-gallon electric heater. 10-2 non-metallic cables … WebAug 18, 2024 · The majority of 50-gallon water heaters will need a 25 to 30-amp circuit breaker. Most of these heaters have 4,500-watt heating elements. But, since 50-gallon tanks are recommended for families of 3 to 4 people, aim for the 30-amp. It’s safe to assume your household uses a lot of water, so the larger breaker will avoid frequent tripping. WebJun 16, 2015 · My current Local code requires #10 wire and 25 amp breaker A 4500 watt element draws 18.75 amps at 240 volts. Code requires wire sized at 125% of continuous load. 18.75 x 1.25= 23.5 Amps. My previous local county building dept allowed a 30 amp breaker w/#10 wire for a 4500 element WH. how to stop dogs chasing chickens